This page lists the technical specifications for Multisensor 6 and form part of the larger Multisensor 6 user guide.
Name: Multisensor 6
Model number: ZW100
Product Weight: 65 g
Total Package Weight: 102 g
Product Dimensions: 47 x 47 x 38 mm
Package Dimensions: 75 x 90 x 50 mm
Backmount Plate Dimensions: 24 x 27 mm
UPC/EAN:
US: 810667023201
EU: 1220000013100
AU: 1220000013094
Z-Wave Plus Certified: Yes
Power supply:
USB DC 5V
battery power (2×CR123A batteries, 3V, 1500mAh).
Not compatible to rechargeable CR123A batteries (3.7V)
Maximum power consumption during a report: 200mA
Voltage input:
USB power
Battery Power
Repeater:
USB power - Yes
Battery Power - No
Sensor Technical information:
Measured temperature range:
-10°C to 50°C
14°F to 122°F.
Temperature Accuracy:
±1°C
±1.8°F.
Measured humidity range: 20%RH to 90%RH.
Humidity Accuracy: ±3%RH (at 25°C/77°F).
Lighting: 0 LUX to 30000 LUX.
UV Range: 0 to 10 UV index
Operating humidity: 8% to 80%.
Operating temperature:
0°C to 40°C
32°F to 104°F.
Max motion sensitivity:
5 metres.
15 feet.
Water proofing: IP20 rating
Battery Life: ~1.5 years using 2x CR123A batteries
- If the MS6 is triggered 20 times per a day, using 2 batteries, the MS6 will last 1.5 years on battery life
- If the MS6 is triggered 200 times per a day using 2 batteries, the MS6 will last around 2-3 months.
Operating distance:
Up to 492 feet outdoors.
Up to 150 metres outdoors.
Supported Commands.
Non-Secure | Secure | |
Node Info Frame | COMMAND_CLASS_ZWAVEPLUS_INFO V2,COMMAND_CLASS_VERSION V2, COMMAND_CLASS_MANUFACTURER_SPECIFIC, COMMAND_CLASS_ASSOCIATION_GRP_INFO, COMMAND_CLASS_ASSOCIATION V2, COMMAND_CLASS_POWERLEVEL V1, COMMAND_CLASS_NOTIFICATION_V3, COMMAND_CLASS_WAKE_UP V2, COMMAND_CLASS_BATTERY V1, COMMAND_CLASS_SENSOR_BINARY V1, COMMAND_CLASS_SENSOR_MULTILEVEL_V5, COMMAND_CLASS_CONFIGURATION V1, COMMAND_CLASS_SECURITY V1, COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2, COMMAND_CLASS_DEVICE_RESET_LOCALLY, COMMAND_CLASS_MARK V1, | COMMAND_CLASS_ZWAVEPLUS_INFO V2 COMMAND_CLASS_VERSION V2 COMMAND_CLASS_WAKE_UP V2 COMMAND_CLASS_MANUFACTURER_SPECIFICV2 COMMAND_CLASS_SECURITY V1 COMMAND_CLASS_DEVICE_RESET_LOCALLY V1 COMMAND_CLASS_MARK V1 |
Security Command Supported Report Frame | COMMAND_CLASS_ZWAVEPLUS_INFO, COMMAND_CLASS_VERSION, COMMAND_CLASS_MANUFACTURER_SPECIFIC, COMMAND_CLASS_WAKE_UP, COMMAND_CLASS_ASSOCIATION_GRP_INFO, COMMAND_CLASS_ASSOCIATION, COMMAND_CLASS_POWERLEVEL, COMMAND_CLASS_NOTIFICATION_V3, COMMAND_CLASS_BATTERY V1, COMMAND_CLASS_SENSOR_BINARY V1, COMMAND_CLASS_SENSOR_MULTILEVEL_V5, COMMAND_CLASS_CONFIGURATION, COMMAND_CLASS_SECURITY, COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 |
Notification/Alarm CC of MultiSensor 6:
Notification Type | Notification Events | Description | ||
Home Security | 0x07 | Previous Events cleared | 0x00 | Motion is cleared |
Motion Detection Unknown Location | 0x08 | Motion is detected | ||
Tampering Product covering removed | 0x03 | Vibration is triggered |
Engineering Sheets: