This page lists the technical specifications for Nano Switch and form part of the larger Nano Switch user guide.


Name: Nano Switch

Model number: ZW116 (with energy reading) / ZW139 (no energy reading) 

Power input: 120 to 240VAC, 50/60Hz.

Repeater: Yes

Beaming: Yes

AES 128 Security: Yes

Power Input:


Version
Input/Output
Working Band
AU
230V 50Hz, Max: 10A
921.42MHz
BR
220V 60Hz, Max: 10A
921.42MHz
CN
220V 50Hz, Max: 10A
868.42MHz
EU
230V 50Hz, Max: 10A
868.42MHz
IL
230V 50Hz, Max: 10A
868.42MHz
IN
230V 50Hz, Max: 10A
865.22MHz
UK
230V 50Hz, Max: 10A
868.42MHz
US
120V 60Hz, Max: 15A
908.42MHz


All versions are compatible to these voltage levels:

110/120VAC 50/60Hz with Max: 15A (1 phase only)

or 220-240VAC 50/60Hz with Max: 10A. (1 phase only)


Max standby power: <0.8W. 

Energy Measurement Input Voltage Required (ZW116 only): 

90 - 240VAC required to power and allow energy reading.

Power measurement accuracy (ZW116 only): + or - 3W.

Dimensions: 42.5 x 40 x 20 mm (1.7 x 1.6 x 0.8 in)

Varistor specifications: 

DIP

07D471K

470VAC

30J ± 10%

9×12×3.8 mm

Accepted Input for L:

90 - 240VAC @ 50/60Hz

24VDC

IN/OUT terminal isolation from L/N:

ZW116 (with metering): No.

ZW139 (without metering): Yes.

External Switch Voltage Requirements:

S1 and S2 inputs the voltage inputted between L and N terminals.

L and N inputted with 90 - 240VAC, then the external switch must also be powered by 90 - 240VAC to S1 or S2 connection.

L and N inputted with 24VDC, then the external switch must also be powered by 24VDC to S1 or S2 connection.

Environment of Installation:

Must be installed indoors

Should be located in a dry location

Should be installed in a fire resistant plastic gangbox.

Should not be installed in a metal gangbox for optimization of Z-Wave range.

Operating temperature: 

0℃ to 40℃

32 ℉ to  104 ℉ .

Relative humidity: 8% to 80%.

Operating distance: 

Up to 492 feet outdoors.

Up to 150 metres outdoors.