This page lists the technical specifications for Nano Switch and form part of the larger Nano Switch user guide.
Name: Nano Switch
Model number: ZW116 (with energy reading) / ZW139 (no energy reading)
Product Dimensions: 42.5 x 40 x 20 mm
Package Dimensions: 73 x 73 x 30 mm
Product Weight: 30 g
Total Package Weight: 57 g
UPC/EAN (ZW116):
US: 810667023881
EU: 1220000015333
AU: 1220000015319
UPC/EAN (ZW139):
US: 810667023744
EU: 1220000015050
AU: 1220000015036
Power input: 120 to 240VAC, 50/60Hz.
Repeater: Yes
Beaming: Yes
AES 128 Security: Yes
Power Input:
Version | Input/Output | Working Band |
AU | 230V 50Hz, Max: 10A | 921.42MHz |
BR | 220V 60Hz, Max: 10A | 921.42MHz |
CN | 220V 50Hz, Max: 10A | 868.42MHz |
EU | 230V 50Hz, Max: 10A | 868.42MHz |
IL | 230V 50Hz, Max: 10A | 868.42MHz |
IN | 230V 50Hz, Max: 10A | 865.22MHz |
UK | 230V 50Hz, Max: 10A | 868.42MHz |
US | 120V 60Hz, Max: 15A | 908.42MHz |
All versions are compatible to these voltage levels and max currents:
110/120VAC 50/60Hz (1 phase only)
Resistive Max: 15A
Inductive Max: 5A
Capacitive Max: 3.5A
220-240VAC 50/60Hz (1 phase only)
Resistive Max: 10A
Inductive Max: 5A
Capacitive Max: 3.5A
Max standby power: <0.8W.
Energy Measurement Input Voltage Required (ZW116 only):
90 - 240VAC required to power and allow energy reading.
Power measurement accuracy (ZW116 only): + or - 3W.
Varistor specifications:
DIP
07D471K
470VAC
30J ± 10%
9×12×3.8 mm
Accepted Input for L:
90 - 240VAC @ 50/60Hz
24VDC
IN/OUT terminal isolation from L/N:
ZW116 (with metering): No.
ZW139 (without metering): Yes.
External Switch Voltage Requirements:
S1 and S2 inputs the voltage inputted between L and N terminals.
L and N inputted with 90 - 240VAC, then the external switch must also be powered by 90 - 240VAC to S1 or S2 connection.
L and N inputted with 24VDC, then the external switch must also be powered by 24VDC to S1 or S2 connection.
Environment of Installation:
Must be installed indoors
Should be located in a dry location
Should be installed in a fire resistant plastic gangbox.
Should not be installed in a metal gangbox for optimization of Z-Wave range.
Operating temperature:
0℃ to 40℃
32 ℉ to 104 ℉ .
Relative humidity: 8% to 80%.
Operating distance:
Up to 492 feet outdoors.
Up to 150 metres outdoors.