This page lists a method of use  Radiator Thermostat with Door/ Windows Sensor 7 and forms a part of the larger Radiator Thermostat user guide.


With this solution, it is possible to set the heating to be switched off when the windows are open and on again when the windows are closed using Door / Window Sensor 7.


1. Pairing both devices in your Hub/Controller


1.1 Pairing Radiator Thermostat into your Z-Wave Network.

1.1.1. Start Inclusion/Pair/Add mode of your primary Z-Wave Controller.
1.1.2. Press the Boost-Button once on Radiator Thermostat. 

1.1.3. Aeotec Radiator Thermostat will show the assigned NodeID provided by the Z-Wave Controller.



1.1.4. If the inclusion failed, "ERR" will appear on the display and the LED will light red. If this happens, try factory resetting Radiator Thermostat and restart the steps for Z-Wave inclusion from step 1.


Note: More information about the Radiator Thermostat setup process can be found in the user guide.


1.2 Adding your Door / Windows Sensor 7 to Z-Wave network.

1.2.1 Set your Z-Wave controller into pairing mode.

1.2.2 Triple-click the tamper switch on Door / Window Sensor 7 - the LED will blink up to five times

1.2.3 After completion of the inclusion, it lights up once before it goes out.

1.2.4 Close the cover



Note: More information about the Door/Window Sensor 7 setup process can be found in the user guide.


2. Change parameters 7 and 8 of Door/Window Sensor 7


Note: How this works can be found in the manual of the gateway you are using.


Thermostat Basic Mode


2.1 Set Parameter 7 [1 byte] to Value 15 (0x0F) 


Parameter 7: Values of ON command frame sent to Group 2 Association.

The value of 0 turns OFF the device, 255 turns it On. In the case of associating the Dimmer or Roller Shutter module, values

Size: 1 Byte, Default Value: 255

SettingDescription
0 - 99allow setting an Associated device to a specified level (0 is OFF)
255ON


2.2 Set Parameter 8 to Value 255 (0xFF)


Parameter 8: Value of OFF command frame sent to Group 2 Association.

The value of 0 turns OFF the device, 255 turns it On. In the case of associating the Dimmer or Roller Shutter module, values.

Size: 1 Byte, Default Value: 0

SettingDescription
0 - 99allow setting an associated device to a specified level. (0 is OFF)
255ON


2.3 Wake the Door Window Sensor 7 to accept the parameter setting changes.


Note: With Parameters 9 and 10 of the Door/Windows Sensor 7 you can set a delay of the action ON or OFF. These can be found in the Door/Windows Sensor 7 user guide.


3. Set Association Group


Note: How this works can be found in the manual of the gateway you are using.


Association Groups of Door/Windows Sensor 7:


Group NumberMaximum NodesDescription
15Lifeline
25Control devices when magnet or external dry contacts trips
35Sends our alarm message when magnet controlled or external dry sensor trips.
45Sends alarm messages when tamper is tripped


3.1 Associate the Radiator Thermostat with the Door/Windows Sensor 7 by connecting the Radiator Thermostat to association group 2 of the Door/Windows Sensor 7.


3.2 Wake the Door Window Sensor 7 to accept the settings.