Name: Multisensor Gen5

Model number: ZW075

Power Supply: 

USB DC 5V

battery power(4×AAA batteries). 

Repeater:

USB power - Yes

Battery Power - No

Operating Temperature: 

-10 C to 60 C.

14 F to 140 F.

Measured Temperature Sensor Range: 

-10 C to 50 C. 

14 F to 122 F.

Measured Temperature Sensor Accuracy:

±1°C

±1.8°F.

Humidity Sensor Range: 20% to 80%. 

Humidity Sensor Accuracy: ±5% (at 25 C). 

Lighting Range: 0 to 1000 LUX.

Motion Sensitivity: 3 to 5 meters (~9 to 15 feet).
Water Proofing: IP42.
Operating distance: 

Up to 492 feet outdoors.

Up to 150 metres outdoor.


Supported Commands.


Non-Secure Secure
Node Information Frame COMMAND_CLASS_VERSION V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC V2
COMMAND_CLASS_ZWAVEPLUS_INFO V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO V1
COMMAND_CLASS_ASSOCIATION V2
COMMAND_CLASS_POWERLEVEL V1
COMMAND_CLASS_NOTIFICATION V3
COMMAND_CLASS_WAKE_UP V2
COMMAND_CLASS_BATTERY V1
COMMAND_CLASS_SENSOR_BINARY V1
COMMAND_CLASS_SENSOR_MULTILEVEL V5
COMMAND_CLASS_CONFIGURATION V1
COMMAND_CLASS_SECURITY V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD V2
COMMAND_CLASS_MARK V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY V1
COMMAND_CLASS_HAIL V1
COMMAND_CLASS_ZWAVEPLUS_INFO V2
COMMAND_CLASS_VERSION V2
COMMAND_CLASS_WAKE_UP V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC V2
COMMAND_CLASS_SECURITY V1
COMMAND_CLASS_MARK V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY V1
COMMAND_CLASS_HAIL V1
Security Command Supported Report Frame
COMMAND_CLASS_ASSOCIATION_GRP_INFO V1
COMMAND_CLASS_ASSOCIATION V2
COMMAND_CLASS_POWERLEVEL V1
COMMAND_CLASS_NOTIFICATION V3
COMMAND_CLASS_BATTERY V1
COMMAND_CLASS_SENSOR_BINARY  V1
COMMAND_CLASS_SENSOR_MULTILEVEL V5
COMMAND_CLASS_CONFIGURATION V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD  V2