Hubitat will automatically use the correct driver for your MultiSensor 7 while connected. This guide will lead you through connecting your MultiSensor 7 to your Hubitat hub and will feature:


  • Motion
  • Temperature
  • Humidity
  • Illuminance
  • ultravioletIndex
  • Battery
  • powerSource




Steps to connect MultiSensor 7 to Hubitat.

  1. Open your Hubitat interface.
  2. Click on Devices.
  3. Click on Discover Devices.
  4. Click on Z-Wave.
  5. Click on Start Z-Wave Inclusion.
  6. Now tap the Action Button on MultiSensor 7.
  7. A device box should appear almost immediately, give it about 10 seconds to initialize, feel free to name your device and save this.




How to remove or factory reset MultiSensor 7 from Hubitat.

  1. Open your Hubitat interface.
  2. Click on Devices.
  3. Click on Discover Devices.
  4. Click on Z-Wave.
  5. Click on Start Z-Wave Exclusion.
  6. Now tap the Action Button on MultiSensor 7.
  7. Your Hubitat should tell you if it excluded an unknown device or a specific sensor if it was paired properly previously.




Troubleshooting


Having issues pairing your device?

  • Move your Sensor within 4 - 10 ft of your Hubitat Z-Wave network.
  • Remove power from MultiSensor 7 for 1 minute, then power it up again.
  • Try factory resetting or removing your MultiSensor 7.
    • Remove / Factory Reset first in case the device actually paired to Hubitat otherwise it will leave a phantom device in your network that will be difficult to remove.
    • Perform a manual factory reset - only do this if you are not able to perform the remove steps above.
      1. Press and hold the Action Button for 20 seconds when it is completed, the LED will become solid green for 2 seconds, and then start to fade a blue color in/out for at least 10 seconds to indicate it is ready to be connected to a new hub.